The target’s Style limit is equal to or higher than the source’s: the Style is read as it is and written in the Pa700 layout.
Pa900 → Pa700 SET conversion
Arrangium converts a Pa900 SET into a Pa700 SET. This direction was measured at file level on real SETs. Below you can see what happens to each type of content in this direction.
Pa900 and Pa700, side by side.
The file layouts of the two models. Rows that differ are marked: that is where the conversion does its work.
DIFFERENT · 8 / 12Pa900 → Pa700: what carries over, what changes?
Each card is one content type. The rules are read from the app’s code.
Sounds are written from the PCG v3.0 layout to the PCG v5.0 layout. Factory Sounds are remapped by name or by address.
User samples and multisamples are written in the Pa700 SET’s layout; the sample itself does not change.
If the SET does not fit, it is measured first and made to fit with Fit to RAM or REMAP. A conversion that does not fit is rolled back and the reason is stated.
PerformancesPerformanceOn the Pa3X and earlier generations, stores the keyboard sounds and settings. The Pa4X generation and the Pa5X use the Keyboard Set for this; the two are not identical.Stored in: .PRF are re-encoded in the target’s layout; the version is lowered going down and kept going up.
There is no converter between VOC v3/v4 and VOC v6.
Set Migrator moves the SongBook to the Pa700 SET: if its versions are ones also seen in Pa700 SETs, it copies them as they are; if not, it rewrites the songs with the Pa700 template. Set Lists carry over only if they are in a version Pa700 reads.
Both models carry quarter-tone presets.
Set Migrator takes the Pa700 factory GLOBAL as its base and writes these from the Pa900 SET: master tuning, scale, key, style group levels, velocity curve and MIDI presets. My Setting, bank names and language stay at the Pa700 factory values.
How was this direction tested?
Set Migrator’s matrix check runs this direction on real SETs: the SET is converted, read back from disk and validated. Cases that do not fit the target are rolled back by design.
- 1CONVERT
- 2READ-BACK
- 3VALIDATE
The way back, and nearby directions.
Questions about Pa900 → Pa700
Yes. The Pa900 → Pa700 direction was converted at file level on real SETs and read back. If a SET does not fit the target, the job is rolled back and the reason is stated.
User samples and multisamples are written in the Pa700 SET’s layout; the sample itself does not change.
Voice Presets are not carried over
Move your Pa900 SET to a Pa700 SET.
Arrangium is not on sale yet. Leave your email on the home page and we will tell you when it launches.
Get notified at launch 4 DECEMBER 2026 · WINDOWS 10 / 11